RMA 202-25 RMA Liquid Flux

E-mail Print PDF

DESCRIPTION

RMA 202-25 is a medium solids, mildly activated liquid flux with a solvent rosin activation formulated to provide a post-process flux residue that is both insulating and non-hydroscopic and does not require cleaning. As a mildly activated rosin based flux, RMA 202-25 offers a wide process window, good cleaning properties, and excellent thermal transfer.

 

 

FEATURES

  • ROSIN ACTIVATED
  • IMPROVED SOLDERING PERFORMANCE
  • NON CORROSIVE RESIDUES
  • RESIDUES REMOVABLE WITH A SAPONIFIER
  • NON-HYDROSCOPIC RESIDUES
  • CAN BE FOAMED, SPRAYED, DIPPED OR BRUSHED

** Passes IPC SIR. Testing results available upon request. Complies with IPC-J-STD-004 and MIL-STD-F14256.

Solids Content

25%

Flux Density

.84 ± .02

Acid Number

40.5 ± .05

HANDLING

  • RMA 202-25 has an unopened shelf life of 1 year when stored at room temperature.
  • Do not store near fire or flame. Keep away from sunlight as it may degrade product.
  • RMA 202-25 is shipped ready-to-use, no mixing is necessary.
  • Do not mix used and unused chemical in the same container. Reseal any opened containers.

FLUX APPLICATION

• When being used for rework, application should be limited to the area being worked. AIM Flux Dispensers or a cotton swab are recommended for localized flux application.

• For most tinning operations, the component lead should be immersed into the flux to a depth of approximately 50% of the desired solder flow in order to prevent excessive flux application.

• For spray fluxing applications, RMA 202-25 is ready to use directly from its container, no thinning is required.

• When spray fluxing, it is imperative that proper flux coverage and uniformity be achieved and maintained. A dry flux coating of 500 to 1500 micrograms per square inch is recommended as a starting point.

• When foam fluxing, air stones should be supplied with compressed air, free of oil and moisture. Adjust foam head to achieve a uniform distribution of small bubbles for optimum flux coverage.

• During foaming applications it is periodically necessary to add flux thinner to replace that which is lost through evaporation. AIM Common Flux Thinner is recommended.

PROCESS CONTROL

Specific gravity should be monitored and controlled either with automated equipment or manually with a hydrometer. Specific gravity should be maintained at .84 ± .02 for optimum performance. Dump and refill flux pot with fresh flux at least once per week when used daily. For spray flux applications, ensure that proper coverage of pwb is maintained.

 

RMA 202-25 LIQUID FLUX Thermal Profile.

 

 

FLUX TECH-TIPS

PROBLEM and POTENTIAL CAUSE

  • BRIDGING: INSUFFICIENT FLUX, EXCESSIVE PRE-HEAT, EXCESS CONVEYOR SPEED, SOLDER CONTAMINATION
  • SOLDER BALLS: LOW PREHEAT TEMPERATURE, EXCESS FLUX
  • WHITE RESIDUE: EXCESS FLUX, FLUX CONTAMINATION, SOLDER CONTAMINATION
  • DISCOLORED JOINT: SOLDER OXIDATION, BOARD/COMPONENT CONTAMINATION, EXCESSIVE HEAT

Add this to your website
 

Chemtools PCB Wash

Chemtools PCB Wash is an aquous blend of biodegradable solvents formulated to remove flux residues and greases.

PCB Wash is ozone friendly and low activity towards metals. It is available in a range of sizes for use in ultrasonic cleaning tanks and manual cleaning.

Chemtools Australian Made Chemtools PCB Wash

 

 

SMT Adhesives & Potting Compounds

You are here: Fluxes RMA RMA 202-25 RMA Liquid Flux